Home Enquiry Form Quotation Request Forms Brochure Request Form What's New Product Lists Product User Manuals Product Technical Notes Ultrasound Equipment Ultrasound Transducers Pre-Plugged Seed Needles Seeding/Biopsy Steppers Disposable Grids Disposable Drapes Endocavity Balloons Grid Adapters PAL Pro Stirrups OR Tables / Trolleys Source Measurement Electrometers Equipment Services Suggestions FAQ Search Useful Web Sites Training Courses Calibrations and Upgrades Intravascular Brachy LDR Calibrations Prostate Brachytherapy 3D Prostate Mapping Prostate Cancer Prostate Seed Implant Mammography/Diagnostics Exradin Ion Chambers Site Map Prostate Scanning SeeDs and Strands Seed Implant Dosimetry HDR/PDR Dose Planning HDR/PDR MultiSource HDR Gynae Applicators HDR Gynae Template LDR/MDR Curietron HDR IU Sleeves HDR/IORT HAM Applicators HDR/IORT Breast Applicator HDR Prostate Brachy HDR Prostate Template AUTIMO Beam Systems Alloys and Alloy Melters Slideshow Bibliography Our Company Curietron Appeal Iridium-192 Wire Sources Eye Applicators Gold Fiduciary Markers Urology Biopsy Biopsy Guns/Needles Needles/Guns/Applications Clinical Oncology Needles Haematology Biopsy Interventional Radiology Urology Needles/Guns Breast Biopsy/Localisation Gynae Biopsy / Aspiration Skin Biopsy Punch Anaesthesia Needles Antenatal Diagnostic Needle Guides Syringe Holders Biopsy Grids Biopsy Steppers Infection Control-MultiMAT Bone Marrow Biopsy Vertebroplasty Laparoscopy Needles Laparoscopy Support Temno Adjustable Coaxial MRI Biopsy/Localisation Percutaneous Injection-PIA
 

 SeeDs and Strands
Home
Enquiry Form
Quotation Request Forms
Brochure Request Form
What's New
Product Lists
Product User Manuals
Product Technical Notes
Ultrasound Equipment
Ultrasound Transducers
Pre-Plugged Seed Needles
Seeding/Biopsy Steppers
Disposable Grids
Disposable Drapes
Endocavity Balloons
Grid Adapters
PAL Pro Stirrups
OR Tables / Trolleys
Source Measurement
Electrometers
Equipment
Services
Suggestions
FAQ
Search
Useful Web Sites
Training Courses
Calibrations and Upgrades
Intravascular Brachy
LDR Calibrations
Prostate Brachytherapy
3D Prostate Mapping
Prostate Cancer
Prostate Seed Implant
Mammography/Diagnostics
Exradin Ion Chambers
Site Map
Prostate Scanning
SeeDs and Strands
Seed Implant Dosimetry
HDR/PDR Dose Planning
HDR/PDR MultiSource
HDR Gynae Applicators
HDR Gynae Template
LDR/MDR Curietron
HDR IU Sleeves
HDR/IORT HAM Applicators
HDR/IORT Breast Applicator
HDR Prostate Brachy
HDR Prostate Template
AUTIMO Beam Systems
Alloys and Alloy Melters
Slideshow
Bibliography
Our Company
Curietron Appeal
Iridium-192 Wire Sources
Eye Applicators
Gold Fiduciary Markers
Urology Biopsy
Biopsy Guns/Needles
Needles/Guns/Applications
Clinical Oncology Needles
Haematology Biopsy
Interventional Radiology
Urology Needles/Guns
Breast Biopsy/Localisation
Gynae Biopsy / Aspiration
Skin Biopsy Punch
Anaesthesia Needles
Antenatal Diagnostic
Needle Guides
Syringe Holders
Biopsy Grids
Biopsy Steppers
Infection Control-MultiMAT
Bone Marrow Biopsy
Vertebroplasty
Laparoscopy Needles
Laparoscopy Support
Temno Adjustable Coaxial
MRI Biopsy/Localisation
Percutaneous Injection-PIA
 


 




 
 

 

 

 

 

 

 

SeeDs and Strands

  IsoSeed
  IsoCord

IsoSeed / IsoCord : New design for excellent X-ray and Ultrasound visibility

A reliable identification of the seeds in X-ray imaging is essential to a successful seed implantation using Flouroscopy for implant depth control. Therefore BEBIG has developed a next generation product and now offers the new IsoSeed I25.S17, which is a seed with excellent X-ray visibility.

IsoSeed I25.S17 is optimised for high –contrast X-ray imaging and enables you to identify seeds easily. The ultrasound visibility of the new product continues to be best in class. Moreover, I25.S17 seeds can be clearly seen in MRI  images. This opens new perspectives for the post planning.

For further details on I25.S17 please refer to the attached IsoSeed I25.S17 Product Information and new IsoSeed and IsoCord brochures.

IsoCord I25.S171 provides excellent strand placement characteristics and an outstanding visibility under X-ray and ultrasound. With the IsoCord Needle Loading Station strand cutting and needle loading is safe and convenient.

 

IsoSeed I-125

The IsoSeed I-125 is an encapsulated sealed radioactive source.


 IsoSeed I-125 Brochure ( pdf )

 
  IsoSeed I25.S17     IsoSeed I25.S06



 
 


 
Optimised for X-ray, ultrasound and MR visibility

 
  Optimised for ultrasound visibility and CT artefact freedom
 
  Packaging and Ordering
IsoSeed is available as loose seeds or loaded in Mick Magazines.
To ensure your safety, our seeds are supplied in a shielded stainless steel container.
Ordering number for seeds loaded in Mick Magazine: I25.S17 SM and I25.S06 SM
Ordering number for loose seeds: I25.S17 SL and I25.S06 SL
 


The Iodine-125 isotope has a half-life of 59.46 days. It decays as a result of electron

capture by X-ray and -emission in the energy range up to 35 keV. The electrons

emitted during the decay process are absorbed by the titanium capsule material,

known as self absorption.
 

Special characteristics of the IsoSeed I-125 and IsoCord

  • Superior CT visibility
    The IsoSeed is equipped with a high-density metal marker providing excellent CT visibility. The full-length marker allows easy and precise location of each seed and produces minimal artefacts. This enhances the precision of the post-implant quality control.

     
 
  • Excellent seed characteristics
    The symmetrical and uniform distribution of the activity throughout the IsoSeed results in an exceptionally low anisotropy. This assures a more homogeneous dose distribution around each seed, a key feature to minimize cold spots in the targeted treatment area.
  •  Excellent flouroscopy visibility
    The implanted IsoCord® strands show up on a fluoroscopic image as a regular pattern. The strands lie in straight lines and the seeds are clearly visible and can be easily identified due to their full length metal marker.



     

  •  Clear ultrasound    visibility
    The
    IsoSeedâ seeds and IsoCord® strands are clearly visible under ultrasound imaging, which allows the use of longitudinal ultrasound scanning for controlling the implant depth.
 
  • MRI compatibility

    The IsoSeedâ seeds and IsoCordâ strands do not contain significant amounts of ferromagnetic material. Isocord / IsoSeed implants will not cause any residual forces inside the magnetic field of an MRI devices which could harm the patient.The conductive parts are also very small so that interactions with the RF frequency will not lead to a noticeable rise of the tissue temperature.

    MR Image of an IsoCord Implant

         

     

  • 100% Quality assurance
    Our highly automated manufacturing process using robotics ensures that each
    IsoSeed is uniform and consistent. Every seed is controlled extensively during the production process by unique automatic measurement systems as well as quality control experts.

  • Flexibility
    IsoSeed allows you to choose your preferred technique. IsoSeeds are available in preloaded Mick cartridges or as loose seeds.

  • More radiation protection for your team

If IsoSeed is used in conjunction with a Mick cartridge and Mick applicator or as IsoCord using the IsoCord Needle Loading Station there will be less exposure to the team handling these seeds than if they were used as loose seeds that need to be loaded into needles.

 

  • Wide activity range
    We provide a broad range of standard activities, which enables you to choose the ideal seed activity for each patient and the technique you employ. Further activities are available upon request.

Class

Air kerma
in µGy m2/h

Apparent activity
in mCi

Apparent activity
in MBq

-3

0.258 - 0.278

0.203 - 0.219

7.50 - 8.12

-2

0.279 - 0.302

0.220 - 0.238

8.13 - 8.82

-1

0.303 - 0.328

0.239 - 0.258

8.83 - 9.56

0

0.329 - 0.356

0.259 - 0.280

9.57 - 10.37

1

0.357 - 0.386

0.281 - 0.304

10.38 - 11.26

2

0.387 - 0.419

0.305 - 0.330

11.27 - 12.22

3

0.420 - 0.455

0.331 - 0.358

12.23 - 13.26

4

0.456 - 0.493

0.359 - 0.388

13.27 - 14.37

5

0.494 - 0.535

0.389 - 0.421

14.38 - 15.59

6

0.536 - 0.581

0.422 - 0.457

15.60 - 16.92

7

0.582 - 0.630

0.458 - 0.496

16.93 - 18.37

8

0.631 - 0.683

0.497 - 0.538

18.38 - 19.92

9

0.684 - 0.742

0.539 - 0.584

19.93 - 21.62

10

0.743 - 0.805

0.585 - 0.634

21.63 - 23.47

11

0.806 - 0.874

0.635 - 0.688

23.48 - 25.47

12

0.875 - 0.948

0.689 - 0.746

25.48 - 27.62

13

0.949 - 1.028

0.747 - 0.809

27.63 - 29.95

14

1.029 - 1.115

0.810 - 0.878

29.96 - 32.50

15

1.116 - 1.210

0.879 - 0.953

32.51 - 35.27

16

1.211 - 1.313

0.954 - 1.034

35.28 - 38.27

17

1.314 - 1.425

1.035 - 1.122

38.28 - 41.53

18

1.426 - 1.546

1.123 - 1.217

41.54 - 45.04

19

1.547 - 1.678

1.218 - 1.321

45.05 - 48.89

20

1.679 - 1.820

1.322 - 1.433

48.90 - 53.03

21

1.821 - 1.975

1.434 - 1.555

53.04 - 57.55

22

1.976 - 2.142

1.556 - 1.687

57.56 - 62.42

 

IsoCord

IsoCord is composed of the established BEBIG IsoSeed I-125, spacers separating the seeds and incorporated within suture material. The suture material and spacers are completely biodegradable within the body.

IsoCord Product Information Brochure ( pdf )
                                
  • Customisation
    IsoCord Seed Chains are wound in a magazine (reel) and can be customized according to your individual needs using the IsoCord Needle Loading Station. i.e. the length of the IsoCord to be implanted can be cut accordingly.
     
  •  Radiation Protection
    The IsoCord Stainless Steel Magazine in conjunction with the needle loading station offers superb radiation protection for the user throughout the procedure.
  • Application
    The IsoCord Needle Loading Station precisely separates the seed chain allowing smooth manoeuvring throughout the needle and easy deposition into the prostate without any jamming. The IsoCord Spacers prevent the accordion effect i.e. the shortening of the distance between seeds in the needle or the prostate during the implantation process. The seeds remain in their determined positions.
  • Implant
    The IsoCord Seed Chain with its very stable initial stiffness provides seed fixity once it is deposited in the prostate. The hour-glass shape of the spacers facilitate rapid degradation within the tissue.
  • Magazine
    The IsoCord Magazine functions both as a transport container and a drive for the IsoCord Seed Chain in the needle loading station. With the drive in the magazine the IsoCord Seed Chain can be manually advanced in the needle loading station. When not used in conjunction with the needle loading station the drive is automatically secured.

  • Miscellaneous
    The IsoCord Magazine is delivered in a double sterile packaging to offer an optimally sterile product. The biocompatibility of the IsoCord Seed Chain has been proven by extensive tests.
  • IsoCord Needle Loading Station ( NLS )

    To cut IsoCord an IsoCord magazine is inserted into the Needle Loading Station. By turning the knob the desired length of IsoCord is moved out of the magazine. The lighted mirror enables you to verify the number and position of the seeds. Next the IsoCord is cut to the appropriate length with the integrated cutting unit and pushed into the implantation needle with the integrated mandrel. The implantation needle is simply attached to the Needle Loading Station by a “push and click” mechanism.The IsoCord strand loaded needle can then be transferred to the IsoCord needle rack for temporary storage or directly into a needle cradle.

              IsoCord Needle Rack                            

              Stainless steel pre-sterilized implant needle rack for temporary

              storage of the IsoCord strand loaded implant needles. Provided with the

              Needle Loading Station ( NLS )                                                                  

  • IsoCord Seed Strand Measurement

           A special seed strand SourceCheck measurement chamber is provided to check         

           measure the activity of the cut IsoCord seed strand.

 

          SourceCheck

 
 
Order number and total number of Seeds in IsoCord


IsoCord is available in the classes 1-14
(see activity range IsoSeed)
 Order-No. Total Number of Seeds
 I25.S061-50 50
 I25.S061-60 60
 I25.S061-70 70

Fast and reliable delivery


The manufacturer BEBIG GmbH is located in the heart of Europe we ensure rapid and reliable seed delivery, which facilitates flexible implant scheduling. Both SeeDOS Ltd and BEBIG GmbH provide customer service in the UK and Ireland.
 


Further information regarding the physical characteristics and indications for use can be found in the Instructions for use (360k).

Detailed information pertaining to the implantation of IsoSeed can be found in our customer information section OR category:

Prostate Brachytherapy, Ultrasound interactive seed-implantation with applicator    (74k)
Permanent Prostate Seed Implantation, Preloading Technique (65k)
CT based dosimetry after prostate brachytherapy with I-125 seeds (78k)

Information for your patients can be found in the patient brochure.



 

TOP OF PAGE

Please contact Colin Walters at cwalters@seedos.com if you would like further  information or you have questions

or comments about this web site.
SeeDOS Ltd, 26, The Maltings,Leighton Buzzard, Bedfordshire LU7 4BS, United Kingdom
Tel: +44 1525 850 670  • Fax: +44 1525 850 685

Please contact SeeDOS Ltd Enquiries at enquiries@seedos.com if you would like further product or service information, a quotation or you have questions

or comments about this web site.
SeeDOS Ltd, 26, The Maltings, Leighton Buzzard, Bedfordshire LU7 4BS, United Kingdom
Tel: +44 1525 850 670  • Fax: +44 1525 850 685


 

SeeDOS Ltd
Radiation Oncology Equipment and Services
Colin S Walters Copyright 2002