Home Enquiry Form Quotation Request Forms Brochure Request Form What's New Product Lists Product User Manuals Product Technical Notes Ultrasound Equipment Ultrasound Transducers Pre-Plugged Seed Needles Seeding/Biopsy Steppers Disposable Grids Disposable Drapes Endocavity Balloons Grid Adapters PAL Pro Stirrups OR Tables / Trolleys Source Measurement Electrometers Equipment Services Suggestions FAQ Search Useful Web Sites Training Courses Calibrations and Upgrades Intravascular Brachy LDR Calibrations Prostate Brachytherapy 3D Prostate Mapping Prostate Cancer Prostate Seed Implant Mammography/Diagnostics Exradin Ion Chambers Site Map Prostate Scanning SeeDs and Strands Seed Implant Dosimetry HDR/PDR Dose Planning HDR/PDR MultiSource HDR Gynae Applicators HDR Gynae Template LDR/MDR Curietron HDR IU Sleeves HDR/IORT HAM Applicators HDR/IORT Breast Applicator HDR Prostate Brachy HDR Prostate Template AUTIMO Beam Systems Alloys and Alloy Melters Slideshow Bibliography Our Company Curietron Appeal Iridium-192 Wire Sources Eye Applicators Gold Fiduciary Markers Urology Biopsy Biopsy Guns/Needles Needles/Guns/Applications MRI Biopsy Clinical Oncology Needles Haematology Biopsy Interventional Radiology Urology Needles/Guns Mammography Needles Laparoscopy Needles Gynae Biopsy / Aspiration Skin Biopsy Punch Anaesthesia Needles Antenatal Diagnostic Needle Guides Syringe Holders Biopsy Grids Biopsy Steppers Infection Control Vertebroplasty Bone Marrow Biopsy
 

 Seed Implant Dosimetry
Home
Enquiry Form
Quotation Request Forms
Brochure Request Form
What's New
Product Lists
Product User Manuals
Product Technical Notes
Ultrasound Equipment
Ultrasound Transducers
Pre-Plugged Seed Needles
Seeding/Biopsy Steppers
Disposable Grids
Disposable Drapes
Endocavity Balloons
Grid Adapters
PAL Pro Stirrups
OR Tables / Trolleys
Source Measurement
Electrometers
Equipment
Services
Suggestions
FAQ
Search
Useful Web Sites
Training Courses
Calibrations and Upgrades
Intravascular Brachy
LDR Calibrations
Prostate Brachytherapy
3D Prostate Mapping
Prostate Cancer
Prostate Seed Implant
Mammography/Diagnostics
Exradin Ion Chambers
Site Map
Prostate Scanning
SeeDs and Strands
Seed Implant Dosimetry
HDR/PDR Dose Planning
HDR/PDR MultiSource
HDR Gynae Applicators
HDR Gynae Template
LDR/MDR Curietron
HDR IU Sleeves
HDR/IORT HAM Applicators
HDR/IORT Breast Applicator
HDR Prostate Brachy
HDR Prostate Template
AUTIMO Beam Systems
Alloys and Alloy Melters
Slideshow
Bibliography
Our Company
Curietron Appeal
Iridium-192 Wire Sources
Eye Applicators
Gold Fiduciary Markers
Urology Biopsy
Biopsy Guns/Needles
Needles/Guns/Applications
MRI Biopsy
Clinical Oncology Needles
Haematology Biopsy
Interventional Radiology
Urology Needles/Guns
Mammography Needles
Laparoscopy Needles
Gynae Biopsy / Aspiration
Skin Biopsy Punch
Anaesthesia Needles
Antenatal Diagnostic
Needle Guides
Syringe Holders
Biopsy Grids
Biopsy Steppers
Infection Control
Vertebroplasty
Bone Marrow Biopsy
 


 




 
 

 

 

 

 

 

 

Seed Implant Dosimetry

Treatment Planning

PSID 4.5 ( NEW ) - Upgrades available – Permanent Seed Implant Dosimetry – An innovative software for Prostate Brachytherapy with pre-, interactive online and post planning.



Interactive Online Planning
PSID supports interactive real time planning for transversal and longitudinal ultrasound imaging with precise matching of planned seed positions in relation to actual seed locations. Dose distributions, histograms and their figures of merits e.g. V100, D90 for the prostate or D1 for the urethra, are immediately updated to provide the physician with the most current information. Seed positions are optimised automatically with respect to dose limits for the rectum and urethra.

Automatic Seed Detection
For post planning, PSID provides a state of the art search algorithm that identifies seed positions quickly and precisely – without the need to specify the number of seeds. This results in a substantial reduction in planning time by removing the need to verify every seed position.

Multiple Report Functions
An extensive and customisable report function provides physician defined information and streamlined output.

User Friendly
The PSID user interface features a modern and easy-to-use structure, including customisable tool bars to meet the users’ treatment planning style.

Complete and Comprehensive
The BEBIG version of PSID provides pre-planning from ultrasound images to interactive online planning during surgery followed by post planning of the implant with precise and easy to use comprehensive software.


PSID Features
 
  •  Full compatibility with Microsoft Windows XP
  •  Multilingual user interface
  •  Context sensitive help function
  •  Meets AAPM TG 43 guidelines 

Image Processing
 
  •  Image acquisition from US device via frame grabber
  •  Dicom3 import via TCP/IP network
  •  Import of image files in more than 20 formats, e.g. DICOM, TIFF, BMP, JPEG,  GIF, PNG
  •  All standard template geometries are provided. Unique templates can be defined by the user.
  •  Fast manual contouring of anatomic structures
  •  Automatic interpolation of contours on all intermediate slices

Planning Features
 
  •  Complete and comprehensive software for pre-planning, real time and post planning of prostate seed implants.
  •  Interactive online planning enables comparison of planned seed positions with actual real time positions.
  •  All data are immediately updated and displayed, including source data, histograms, isodoses, and seed placement.
  •  Manual and automatic plan optimisation even for previously placed seeds.
  •  Dose limiting capabilities to areas of interest, e.g. rectum, urethra.
  •  Simple editing (placing, deleting, moving) of seeds or strands
  •  An "undo" function for the last input makes editing of seeds easier.
  •  Display of dose rates and Hounsfield units at any cursor position
  •  2D display of organ contours, isodoses, seeds and needles in sagittal and coronal view as well as user defined angles
  •  3D display of organ contours, needles, seeds and isodoses
  •  Extensive seed library and additionalseed editor
  •  User defined seeds and strands

Documentation
 
  •  All parameters of interest can be displayed online in a separate window.
  •  Extensive and customisable reports

Post Planning
 
  •  Co-registration for image fusion of CT, MR or US image sequences with up to 128 images per sequence
  •  Unique search algorithm for automatic seed detection substantially reduces treatment planning time

Configuration
System consists of:
 
  •  PSID Treatment Planning Software
  •  PSID Notebook
  •  PSID Frame Grabber Set
  •  Inkjet Printer
optional:
 
  •  17" TFT monitor as additional display for the PSID Notebook
  •  A second PSID Notebook with pre-installed PSID as backup
 

Please contact SeeDOS Ltd Enquiries at enquiries@seedos.com if you would like further product or service information, a quotation or you have questions

or comments about this web site.
SeeDOS Ltd, 26, The Maltings, Leighton Buzzard, Bedfordshire LU7 4BS, United Kingdom
Tel: +44 1525 850 670  • Fax: +44 1525 850 685


 

SeeDOS Ltd
Radiation Oncology Equipment and Services
Colin S Walters Copyright 2002
Last Modified : 02/12/10 12:52 PM